Find a PSS Column Application

Column Applications

10021
Characterization of Polysulfone
Recommended Column Combinations:
Low molar mass samples:
P/N 201-0001 (set of 3) OR sda083003lis (1 linear)
Medium molar mass samples:
P/N 201-0002 (set of 2) OR sda083005lim (1 linear)
High molar mass samples:
P/N 201-0003 (set of 3) OR sda083005lxl (1 linear)
Ultrahigh molar mass samples:
P/N 202-0001 (set of 3)
Dimethylacetamide
PSS SDV
lockSign in for PDF
10040
Characterization of Poly(ethersulfone)
Recommended Column Combinations:
Low molar mass samples:
P/N 201-0001 (set of 3) OR sda083003lis (1 linear)
Medium molar mass samples:
P/N 201-0002 (set of 2) OR sda083005lim (1 linear)
High molar mass samples:
P/N 201-0003 (set of 3) OR sda083005lxl (1 linear)
Ultrahigh molar mass samples:
P/N 202-0001 (set of 3)
Dimethylacetamide
PSS SDV
lockSign in for PDF
10030
Characterization of Poly(Norbenyl-Cyclodextrine) Copolymer
Recommended Column Combinations:
Low molar mass samples:
P/N 208-0001 (set of 3)
Medium molar mass samples:
P/N 208-0002 (set of 3) OR ama083010lin (1 linear)
High molar mass samples:
P/N 208-0003 (set of 3)
Ultrahigh molar mass samples:
P/N 208-0004 (set of 3)
Dimethylformamide
PSS GRAM
lockSign in for PDF
10050
Characterization of Poly(acrylonitrile)
Recommended Column Combinations:
Low molar mass samples:
P/N 201-0001 (set of 3) OR sda083003lis (1 linear)
Medium molar mass samples:
P/N 201-0002 (set of 2) OR sda083005lim (1 linear)
High molar mass samples:
P/N 201-0003 (set of 3) OR sda083005lxl (1 linear)
Ultrahigh molar mass samples:
P/N 202-0001 (set of 3)
Dimethylformamide
PSS SDV
lockSign in for PDF
10286
Characterization of Methyl Cellulose
Recommended Column Combinations:
Low molar mass samples:
P/N 208-0001 (set of 3)
Medium molar mass samples:
P/N 208-0002 (set of 3) OR ama083010lin (1 linear)
High molar mass samples:
P/N 208-0003 (set of 3)
Ultrahigh molar mass samples:
P/N 208-0004 (set of 3)
Dimethylsulfoxide
PSS GRAM
lockSign in for PDF
10287
Characterization of Hydroxypropyl Cellulose
Recommended Column Combinations:
Low molar mass samples:
P/N 208-0001 (set of 3)
Medium molar mass samples:
P/N 208-0002 (set of 3) OR ama083010lin (1 linear)
High molar mass samples:
P/N 208-0003 (set of 3)
Ultrahigh molar mass samples:
P/N 208-0004 (set of 3)
Dimethylsulfoxide
PSS GRAM
lockSign in for PDF
10039
Characterization of Poly(ethylene terephthalate)
Recommended Column Combinations:
Low molar mass samples:
P/N 203-0001 (set of 2) OR pfa083007lis (1 linear)
Medium molar mass samples:
P/N 203-0002 (set of 2) OR pfa083007lim (1 linear)
High molar mass samples:
P/N 203-0003 (set of 3) OR pfa083007lxl (1 linear)
Ultrahigh molar mass samples:
-
Hexafluoroisopropanol
PSS PFG
lockSign in for PDF
10043
Characterization of Poly(ethylene imine)
Recommended Column Combinations:
Low molar mass samples:
P/N 203-0001 (set of 2) OR pfa083007lis (1 linear)
Medium molar mass samples:
P/N 203-0002 (set of 2) OR pfa083007lim (1 linear)
High molar mass samples:
P/N 203-0003 (set of 3) OR pfa083007lxl (1 linear)
Ultrahigh molar mass samples:
-
Hexafluoroisopropanol
PSS PFG
lockSign in for PDF
10049
Characterization of Poly(butylene terephthalate)
Recommended Column Combinations:
Low molar mass samples:
P/N 203-0001 (set of 2) OR pfa083007lis (1 linear)
Medium molar mass samples:
P/N 203-0002 (set of 2) OR pfa083007lim (1 linear)
High molar mass samples:
P/N 203-0003 (set of 3) OR pfa083007lxl (1 linear)
Ultrahigh molar mass samples:
-
Hexafluoroisopropanol
PSS PFG
lockSign in for PDF
10053
Characterization of Poly(amide)
Recommended Column Combinations:
Low molar mass samples:
P/N 203-0001 (set of 2) OR pfa083007lis (1 linear)
Medium molar mass samples:
P/N 203-0002 (set of 2) OR pfa083007lim (1 linear)
High molar mass samples:
P/N 203-0003 (set of 3) OR pfa083007lxl (1 linear)
Ultrahigh molar mass samples:
-
Hexafluoroisopropanol
PSS PFG
lockSign in for PDF

Column Applications

No.: 10021
Name: Characterization of Polysulfone
Mobile Phase Dimethylacetamide
Stationary phase PSS SDV
Low molar mass samples: P/N 201-0001 (set of 3) OR sda083003lis (1 linear)
Medium molar mass samples: P/N 201-0002 (set of 2) OR sda083005lim (1 linear)
High molar mass samples: P/N 201-0003 (set of 3) OR sda083005lxl (1 linear)
Ultrahigh molar mass samples: P/N 202-0001 (set of 3)
lockSign in for PDF


No.: 10040
Name: Characterization of Poly(ethersulfone)
Mobile Phase Dimethylacetamide
Stationary phase PSS SDV
Low molar mass samples: P/N 201-0001 (set of 3) OR sda083003lis (1 linear)
Medium molar mass samples: P/N 201-0002 (set of 2) OR sda083005lim (1 linear)
High molar mass samples: P/N 201-0003 (set of 3) OR sda083005lxl (1 linear)
Ultrahigh molar mass samples: P/N 202-0001 (set of 3)
lockSign in for PDF


No.: 10030
Name: Characterization of Poly(Norbenyl-Cyclodextrine) Copolymer
Mobile Phase Dimethylformamide
Stationary phase PSS GRAM
Low molar mass samples: P/N 208-0001 (set of 3)
Medium molar mass samples: P/N 208-0002 (set of 3) OR ama083010lin (1 linear)
High molar mass samples: P/N 208-0003 (set of 3)
Ultrahigh molar mass samples: P/N 208-0004 (set of 3)
lockSign in for PDF


No.: 10050
Name: Characterization of Poly(acrylonitrile)
Mobile Phase Dimethylformamide
Stationary phase PSS SDV
Low molar mass samples: P/N 201-0001 (set of 3) OR sda083003lis (1 linear)
Medium molar mass samples: P/N 201-0002 (set of 2) OR sda083005lim (1 linear)
High molar mass samples: P/N 201-0003 (set of 3) OR sda083005lxl (1 linear)
Ultrahigh molar mass samples: P/N 202-0001 (set of 3)
lockSign in for PDF


No.: 10286
Name: Characterization of Methyl Cellulose
Mobile Phase Dimethylsulfoxide
Stationary phase PSS GRAM
Low molar mass samples: P/N 208-0001 (set of 3)
Medium molar mass samples: P/N 208-0002 (set of 3) OR ama083010lin (1 linear)
High molar mass samples: P/N 208-0003 (set of 3)
Ultrahigh molar mass samples: P/N 208-0004 (set of 3)
lockSign in for PDF


No.: 10287
Name: Characterization of Hydroxypropyl Cellulose
Mobile Phase Dimethylsulfoxide
Stationary phase PSS GRAM
Low molar mass samples: P/N 208-0001 (set of 3)
Medium molar mass samples: P/N 208-0002 (set of 3) OR ama083010lin (1 linear)
High molar mass samples: P/N 208-0003 (set of 3)
Ultrahigh molar mass samples: P/N 208-0004 (set of 3)
lockSign in for PDF


No.: 10039
Name: Characterization of Poly(ethylene terephthalate)
Mobile Phase Hexafluoroisopropanol
Stationary phase PSS PFG
Low molar mass samples: P/N 203-0001 (set of 2) OR pfa083007lis (1 linear)
Medium molar mass samples: P/N 203-0002 (set of 2) OR pfa083007lim (1 linear)
High molar mass samples: P/N 203-0003 (set of 3) OR pfa083007lxl (1 linear)
Ultrahigh molar mass samples: -
lockSign in for PDF


No.: 10043
Name: Characterization of Poly(ethylene imine)
Mobile Phase Hexafluoroisopropanol
Stationary phase PSS PFG
Low molar mass samples: P/N 203-0001 (set of 2) OR pfa083007lis (1 linear)
Medium molar mass samples: P/N 203-0002 (set of 2) OR pfa083007lim (1 linear)
High molar mass samples: P/N 203-0003 (set of 3) OR pfa083007lxl (1 linear)
Ultrahigh molar mass samples: -
lockSign in for PDF


No.: 10049
Name: Characterization of Poly(butylene terephthalate)
Mobile Phase Hexafluoroisopropanol
Stationary phase PSS PFG
Low molar mass samples: P/N 203-0001 (set of 2) OR pfa083007lis (1 linear)
Medium molar mass samples: P/N 203-0002 (set of 2) OR pfa083007lim (1 linear)
High molar mass samples: P/N 203-0003 (set of 3) OR pfa083007lxl (1 linear)
Ultrahigh molar mass samples: -
lockSign in for PDF


No.: 10053
Name: Characterization of Poly(amide)
Mobile Phase Hexafluoroisopropanol
Stationary phase PSS PFG
Low molar mass samples: P/N 203-0001 (set of 2) OR pfa083007lis (1 linear)
Medium molar mass samples: P/N 203-0002 (set of 2) OR pfa083007lim (1 linear)
High molar mass samples: P/N 203-0003 (set of 3) OR pfa083007lxl (1 linear)
Ultrahigh molar mass samples: -
lockSign in for PDF


X

Die Webseite ist für moderne Browser optimiert. In Ihrem Browser können Inhalte fehlerhaft angezeigt werden.