Refine Results
- Products
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
- Compounds
-
Compounds
- Detection Technique
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Need help finding the right GPC/SEC Columns? Try our GPC/SEC Column Selector Tool
Application note for polystyrene stars on Agilent PLgel 5 μm MIXED-C using Gel Permeation Chromatography
- Publication Part Number: 5990-8487EN
- Created: 30 Apr 2015
- 639 KB
Publication Part Number | 5990-8487EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Analysis of polymer molecular weight distributions by conventional gel permeation chromatography requires a retention time and molecular weight calibration curve.
- Publication Part Number: 5990-8425EN
- Created: 30 Apr 2015
- 169 KB
Publication Part Number | 5990-8425EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Agilent PLgel columns can be used in a wide range of solvents, including polar organics, which facilitate the analysis of very polar samples such as polyvinylidene fluoride
- Publication Part Number: 5990-8328EN
- Created: 30 Apr 2015
- 117 KB
Publication Part Number | 5990-8328EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
A gel permeation chromatography system comprising PLgel MIXED-B columns and the PL-GPC 220 integrated, high temperature instrument is ideally suited to the analysis of Polyeth
- Publication Part Number: 5990-8496EN
- Created: 30 Apr 2015
- 183 KB
Publication Part Number | 5990-8496EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
The ability of a GPC system, comprising PLgel MIXED-B columns and the PL-GPC 220 integrated, high temperature instrument, is demonstrated in a repeatability study
- Publication Part Number: 5990-8333EN
- Created: 30 Apr 2015
- 153 KB
Publication Part Number | 5990-8333EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Application note for the analysis of Polythiophenes via Conventional GPC
- Publication Part Number: 5991-5828EN
- Created: 30 Apr 2015
- 727 KB
In this publication we demonstrate how the Agilent PL-GPC 220 High Temperature GPC System can be used to reliably discriminate between long chain branching polyethylene (LDPE)
- Publication Part Number: 5991-2781ENE
- Created: 16 Sep 2014
- 2 MB
Publication Part Number | 5991-2781EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Application note on the analysis of PBT and PET using Agilent PL HFIPgel and PL gel columns with the Agilent PL-GPC 220 High Temperature GPC/SEC System
- Publication Part Number: 5991-4707EN
- Created: 22 May 2014
- 158 KB
Publication Part Number | 5991-4707EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Demonstrates the combination of the OligoPore columns and the PL-GPC 220 a series of hydrocarbon standards were done in trichlorobenzene at 145 ºC.
- Publication Part Number: SI-01734
- Created: 09 June 2011
- 580 KB
Describes how GPC can be combined with Fourier transform-infrared spectroscopy (FTIR) to analyze copolymers and polymer blends.
- Publication Part Number: SI-01912
- Created: 20 Oct 2010
- 104 KB
Seven sections in this eBook describe various powerful GPC/SEC applications and use cases in detail.
- Publication Part Number: 5994-5915EN
- Created: 13 Feb 2024
- 6 MB
Agilent WinGPC Overlapping Injection function enables a sample to be injected before the previous sample has completely eluted, saving solvent and analysis time.
- Publication Part Number: 5994-5948EN
- Created: 14 Aug 2023
- 279 KB
The Agilent WinGPC ChromPilot sequence manager enables the execution of sawtooth gradients with the Agilent 1260 Infinity II GPC/SEC System.
- Publication Part Number: 5994-5946EN
- Created: 14 Aug 2023
- 296 KB
WinGPC Software has automatic flow correction with an internal standard or flow marker to compensate for the negative effects of constantly fluctuating flow rates.
- Publication Part Number: 5994-5940EN
- Created: 14 Aug 2023
- 256 KB
Agilent WinGPC software can be used to extract extensive information from a single injection, including the mass distribution and derived molecular weight averages for up to 8 areas.
- Publication Part Number: 5994-5947EN
- Created: 07 Aug 2023
- 149 KB
This note describes how necessary parameters for all detectors and combinations can be determined using the Agilent WinGPC Software detector setup dialog box.
- Publication Part Number: 5994-5942EN
- Created: 07 Aug 2023
- 268 KB
The Agilent WinGPC 3D spectra Add-On enables recording and visualization of online spectra for each chromatographic slice of a GPC/SEC measurement.
- Publication Part Number: 5994-5916EN
- Created: 21 July 2023
- 386 KB
The Agilent WinGPC Column Database is an integral part of Agilent WinGPC software. This technical overview presents the column database and all its features.
- Publication Part Number: 5994-5944EN
- Created: 21 July 2023
- 289 KB
This technical overview describes several options for exporting files from Agilent WinGPC Software, enabling measurement or results to be approved or filed.
- Publication Part Number: 5994-5943EN
- Created: 21 July 2023
- 551 KB
With Agilent WinGPC Software, the start and end volumes of peaks found in HPLC mode can be transferred to the multi-area analysis tool and used as area definitions.
- Publication Part Number: 5994-5941EN
- Created: 21 July 2023
- 251 KB