Refine Results
- Products
-
Product Category
- Applications and Industries
- Content Type
-
Content Type
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Need help finding the right GPC/SEC Columns? Try our GPC/SEC Column Selector Tool
Determine volumes which do not correspond to a maximum or a minimum, for example when working with a fraction collector.
- Publication Part Number: 5994-6334EN
- Created: 01 Aug 2023
- 344 KB
Quantify the degree of degradation and use the Agilent WinGPC overlay function for sample comparison.
- Publication Part Number: 5994-6327EN
- Created: 01 Aug 2023
- 363 KB
Characterization of ion exchange resins.
- Publication Part Number: 5994-6248EN
- Created: 01 Aug 2023
- 150 KB
Check the performance of your GPC/SEC system with the Agilent WinGPC system test.
- Publication Part Number: 5994-6330EN
- Created: 01 Aug 2023
- 496 KB
Use Agilent WinGPC to control a fraction collector.
- Publication Part Number: 5994-6333EN
- Created: 01 Aug 2023
- 372 KB
Protect the pressure transducers of your viscometer using the Agilent WINChrom interface.
- Publication Part Number: 5994-6326EN
- Created: 01 Aug 2023
- 432 KB
GPC/SEC analysis of dextran sulfate in aqueous solution using Agilent SUPREMA columns.
- Publication Part Number: 5994-6306EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of xanthan in aqueous solution using Agilent SUPREMA columns.
- Publication Part Number: 5994-6254EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of pullulanes in aqueous solution using Agilent SUPREMA columns.
- Publication Part Number: 5994-6260EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of hydroxyethyl starch in aqueous solution using Agilent SUPREMA columns.
- Publication Part Number: 5994-6301EN
- Created: 01 July 2023
- 1 MB
This application note introduces the analysis of dextrans according to a USP/EP monograph by GPC/SEC using a specific e-workflow in Agilent WinGPC.
- Publication Part Number: 5994-5763EN
- Created: 03 Mar 2023
- 149 KB
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
Robust and reliable GPC/SEC analysis of a large variety of saccharides and polysaccharides can be performed with very high resolution using Agilent SUPREMA columns.
- Publication Part Number: 5994-5702EN
- Created: 03 Mar 2023
- 747 KB
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
Seven sections in this eBook describe various powerful GPC/SEC applications and use cases in detail.
- Publication Part Number: 5994-5915EN
- Created: 13 Feb 2024
- 6 MB
Japanese (Japan) | Complete (PDF) |
---|---|
Korean (Korea) | Complete (PDF) |
Chinese (Simplified) (China) | Complete (PDF) |
WinGPC Software has automatic flow correction with an internal standard or flow marker to compensate for the negative effects of constantly fluctuating flow rates.
- Publication Part Number: 5994-5940EN
- Created: 14 Aug 2023
- 256 KB
Agilent WinGPC Overlapping Injection function enables a sample to be injected before the previous sample has completely eluted, saving solvent and analysis time.
- Publication Part Number: 5994-5948EN
- Created: 14 Aug 2023
- 279 KB
The Agilent WinGPC ChromPilot sequence manager enables the execution of sawtooth gradients with the Agilent 1260 Infinity II GPC/SEC System.
- Publication Part Number: 5994-5946EN
- Created: 14 Aug 2023
- 296 KB
This note describes how necessary parameters for all detectors and combinations can be determined using the Agilent WinGPC Software detector setup dialog box.
- Publication Part Number: 5994-5942EN
- Created: 07 Aug 2023
- 268 KB
Agilent WinGPC software can be used to extract extensive information from a single injection, including the mass distribution and derived molecular weight averages for up to 8 areas.
- Publication Part Number: 5994-5947EN
- Created: 07 Aug 2023
- 149 KB
GPC/SEC analysis of human insulin in water/acetic acid/acetonitrile/L-Arginin using Agilent PROTEEMA columns.
- Publication Part Number: 5994-6259EN
- Created: 01 Aug 2023
- 1 MB
GPC/SEC analysis of gelatin in an aqueous phosphate buffer solution using Agilent PROTEEMA columns.
- Publication Part Number: 5994-6270EN
- Created: 01 Aug 2023
- 1 MB