Refine Results
- Products
-
- Applications and Industries
- Content Type
-
Content Type
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Need help finding the right GPC/SEC Columns? Try our GPC/SEC Column Selector Tool
Agilent WinCHROM or the LAN interfaces are equipped with output relays to control valves or to saveguide special instruments such as fraction collectors or viscometers.
- Publication Part Number: 5994-6489EN
- Created: 01 Aug 2023
- 158 KB
For higher sample throughput, the overlaid injection feature of Agilent WinGPC allows to save 30% time between two injections.
- Publication Part Number: 5994-6321EN
- Created: 01 Aug 2023
- 350 KB
Check the long time performance of your GPC/SEC columns to visualize loss in resolution.
- Publication Part Number: 5994-6332EN
- Created: 01 Aug 2023
- 312 KB
Characterize membranes and let WinGPC calculate the molecular cutoff.
- Publication Part Number: 5994-6328EN
- Created: 01 Aug 2023
- 390 KB
Time and solvent for the analysis of a sample on a dedicated column set can be reduced up to 35% with the WinGPC overlaid injection feature.
- Publication Part Number: 5994-6336EN
- Created: 01 Aug 2023
- 204 KB
Determine the structure of your polymer or investigate branching using molar mass sensitive detectors.
- Publication Part Number: 5994-6486EN
- Created: 01 Aug 2023
- 153 KB
Characterization of ion exchange resins.
- Publication Part Number: 5994-6248EN
- Created: 01 Aug 2023
- 150 KB
Divide your sample into different regions and let the Agilent WinGPC software calculate all results simultaneously.
- Publication Part Number: 5994-6492EN
- Created: 01 Aug 2023
- 351 KB
Verify the correct and complete installation of your PSS WinGPC software package.
- Publication Part Number: 5994-6324EN
- Created: 01 Aug 2023
- 508 KB
Investigation of porous nano materials.
- Publication Part Number: 5994-6488EN
- Created: 01 Aug 2023
- 156 KB
The differences between the WinGPC automation feature for active measurements and the WinGPC quick analysis tool are described.
- Publication Part Number: 5994-6335EN
- Created: 01 Aug 2023
- 288 KB
GPC/SEC analysis of hydroxyethyl starch in aqueous solution using Agilent SUPREMA columns.
- Publication Part Number: 5994-6301EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of pullulanes in aqueous solution using Agilent SUPREMA columns.
- Publication Part Number: 5994-6260EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of xanthan in aqueous solution using Agilent SUPREMA columns.
- Publication Part Number: 5994-6254EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of dextran sulfate in aqueous solution using Agilent SUPREMA columns.
- Publication Part Number: 5994-6306EN
- Created: 01 July 2023
- 1 MB
Seven sections in this eBook describe various powerful GPC/SEC applications and use cases in detail.
- Publication Part Number: 5994-5915EN
- Created: 13 Feb 2024
- 6 MB
WinGPC Software has automatic flow correction with an internal standard or flow marker to compensate for the negative effects of constantly fluctuating flow rates.
- Publication Part Number: 5994-5940EN
- Created: 14 Aug 2023
- 256 KB
The Agilent WinGPC ChromPilot sequence manager enables the execution of sawtooth gradients with the Agilent 1260 Infinity II GPC/SEC System.
- Publication Part Number: 5994-5946EN
- Created: 14 Aug 2023
- 296 KB
Agilent WinGPC Overlapping Injection function enables a sample to be injected before the previous sample has completely eluted, saving solvent and analysis time.
- Publication Part Number: 5994-5948EN
- Created: 14 Aug 2023
- 279 KB
This note describes how necessary parameters for all detectors and combinations can be determined using the Agilent WinGPC Software detector setup dialog box.
- Publication Part Number: 5994-5942EN
- Created: 07 Aug 2023
- 268 KB