Refine Results
- Products
- Content Type
-
Content Type
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Need help finding the right GPC/SEC Columns? Try our GPC/SEC Column Selector Tool
GPC/SEC analysis of poly(carbonate urethane) in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6286EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of deuterated poly(styrene) in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6262EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of poly(styrene-butylacrylate) copolymer in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6252EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of poly(ethylene glycol) in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6284EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of poly(styrene) in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6266EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of poly(ethyl methacrylate) in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6282EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of poly(phenyl acetylene)) in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6273EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of hydroxypropyl cellulose ester in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6300EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of poly(butyl methacrylate-styrene) copolymers in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6250EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of poly(vinyl chloride) in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6258EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of poly(ethylene-methacrylate) copolymers in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6305EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of hydroxypropyl cellulose ether in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6299EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of poly(t-butyl acrylate) in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6255EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of poly(isoprene-3.4) in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6317EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of brominated poly(styrene) in tetrahydrofuran using Agilent SDV columns.
- Publication Part Number: 5994-6264EN
- Created: 28 June 2023
- 1 MB
This application brief shows a comparison of oligomeric resolution using Agilent SDV columns with particles sizes of 3, 5, and 10 μm for GPC/SEC measurements.
- Publication Part Number: 5994-5722EN
- Created: 02 Mar 2023
- 175 KB
2-Methyltetrahydrofuran (2-methylTHF) is used as an eluent in GPC/SEC measurements of polystyrene and polymethyl methacrylate with SDV columns.
- Publication Part Number: 5994-5717EN
- Created: 16 Feb 2023
- 177 KB
Stability test of Agilent POLEFIN columns with a broad Poly(ethylene) in trichlorobenzene over 6 months.
- Publication Part Number: 5994-6309EN
- Created: 01 July 2023
- 1 MB
GPC/SEC analysis of Methyl cellulose in dimethyl sulfoxide with lithium bromide using Agilent GRAM columns.
- Publication Part Number: 5994-6311EN
- Created: 01 July 2023
- 2 MB
GPC/SEC analysis of a poly(butylene terephthalate) in hexafluoroisopropanol with potassium trifluoroacetate using Agilent PFG columns.
- Publication Part Number: 5994-6287EN
- Created: 01 July 2023
- 1 MB