Refine Results
- Products
-
Product
- Content Type
-
Content Type
- Inner Diameter
-
Inner Diameter
- Length
-
Length
- Manufacturer Compatibility
-
Manufacturer Compatibility
- Particle Size
-
Particle Size
- Pore Size
-
Pore Size
- Unit Quantity
-
Unit Quantity
- LC Column Brand
-
LC Column Brand
- LC Column Maximum Temperature
-
LC Column Maximum Temperature
- Molecular Weight Lower Limit
-
Molecular Weight Lower Limit
- Molecular Weight Upper Limit
-
Molecular Weight Upper Limit
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Need help finding the right GPC/SEC Columns? Try our GPC/SEC Column Selector Tool
Pre-equilibrated column for low-noise light scattering measurements for organic GPC/SEC analysis
Kits of columns, standards, and everything needed to verify system performance and start analysis
Styrene-divinylbenzene copolymer-based column for organic GPC/SEC analysis of polymers
Column for organic GPC/SEC of solvent-resistant polymers in HFIP and polar fluorinated solvents
Styrene-divinylbenzene copolymer-based column for high-temperature GPC/SEC analysis of polyolefins
Polyester copolymer-based column for organic GPC/SEC of polymers in polar organic solvents
Highest resolution gel permeation chromatography (GPC) within a narrow mol weight range.
Polar modified silica-based column for GPC/SEC of polymers in polar organics such as DMAc and DMSO
Polar modified silica-based column for organic GPC/SEC of crystalline polymer in fluorinated solvent
Column for organic GPC/SEC of polar polymers with polar organic solvents, such as DMF or DMSO
Column for organic GPC/SEC analyses for high resolution, wide calibration, or preparative scale
PL Rapide GPC columns configured to offer high speed and resolution on older systems.
PLgel Olexis GPC columns are designed for analysis of high-mol wt polymers and high-temperature GPC.
Compare
ResiPore, 2.1 x 250 mm, GPC column. Multipore GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 200 Da to 500 kDa
-
Unit:
1 Each
-
Length:
250 mm
Compare
MesoPore, 2.1 x 250 mm, GPC column. Multipore GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 100 Da to 25kDa
-
Unit:
1 Each
-
Length:
250 mm
Compare
PolyPore, 2.1 x 250 mm, GPC column. Multipore GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 200 Da to 2 MDa
-
Unit:
1 Each
-
Length:
250 mm
Compare
OligoPore, 2.1 x 250 mm, GPC column. Multipore GPC/SEC column for non-polar organic eluents e.g., THF, Toluene, Chloroform, to analyze non-polar polymers resolving range 100 Da to 3.3 kDa
-
Unit:
1 Each
-
Length:
250 mm
Compare
PLgel Organic GPC start-up kit. Includes PLgel 5 μm MIXED-C 7.5 x 300 mm column (p/n PL1110-6500), 9 EasiVial PS-M 2 mL vials (3 x red,yellow,green), 3 broad polystyrene standard vials, with certifications and documentation
-
Unit:
1 Kit
-
Length:
300 mm
GRAM, 8 x 50 mm, 10 µm. GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 10µm GRAM analytical columns 8 mm internal diameter
-
Unit:
1 Each
GRAM Lux, 8 x 50 mm, 10 µm. Light-scattering detection ready GPC/SEC guard column to protect and extend the lifetime of analytical columns. Suitable for use with 10µm GRAM analytical columns 8 mm internal diameter
-
Unit:
1 Each