PSS Perfect Separation Solutions > Support > Library/PSS Publications

PSS Library

White Paper


PSS White Paper collection with detailed information to establish trustworthy solutions.

App Notes


Full featured application notes describing how to solve tasks.

E-book Series


Learn more about macromolecules, GPC/SEC and 2D.

GPC/SEC Tips&Tricks


Developed by PSS for LC/GC: Practical tips and advice for GPC/SEC users.

Streamliner


The PSS Company Magazine featuring the latest developments

PSS Publication Database

Publications

GPC/SEC/GFC Calibration
Molar masses cannot be measured directly by GPC/SEC. Direct results of a GPC/SEC run are chromatograms or elugrams, which show the detector signal intensity versus the elution volume. These elugrams…
Language
Publication Number
20451
Publication Type
Webinar/Webcast
Source
PSS Webinar
Year
2016
Publication date
10.03.2016
Issue
4
Author
M. Krämer
GPC/SEC/GFC Calibration
Molar masses cannot be measured directly by GPC/SEC. Direct results of a GPC/SEC run are chromatograms or elugrams, which show the detector signal intensity versus the elution volume. These elugrams…
lockSign in for download
Language
Publication Number
20459
Publication Type
Webinar/Webcast
Source
PSS Webinar
Year
2015
Publication date
15.10.2015
Issue
4
Author
J. Preis, T. Hofe, G. Reinhold, P. Montag
GPC/SEC/GFC Column Selection
Columns are the heart of any GPC/SEC/GFC system. This webinar discusses basic concepts for selecting columns with respect to analytical task, resolution and long term reproducibility. In the…
Language
Publication Number
20453
Publication Type
Webinar/Webcast
Source
PSS Webinar
Year
2016
Publication date
18.02.2016
Issue
4
Author
W. Radke
GPC/SEC/GFC Column Selection
Columns are the heart of any GPC/SEC/GFC system. This webinar discusses basic concepts for selecting columns with respect to analytical task, resolution and long term reproducibility. In the…
Language
Publication Number
20460
Publication Type
Webinar/Webcast
Source
PSS Webinar
Year
2015
Publication date
16.04.2015
Issue
4
Author
T. Hofe
GPC1200 - Neue Wege in der GPC
Was ist das Besondere an einem GPC-System von PSS? In diesem Dokument haben wir die Antworten auf die bei der Analytica 2006 meistgestellten Fragen.
lockSign in for download
Language
Publication Number
30146
Publication Type
WinGPC Application
Source
PSS WinGPC Newsletter
Year
2006
Publication date
30.06.2006
Issue
2
Greener GPC/SEC
Scope of this White Paper: - Discuss less hazardous solvent alternatives from renewable resources which can be successfully applied for size separation of macromolecules - Describe options for users…
Language
Publication Number
20542
Publication Type
White Paper/Primer
Source
PSS White Paper
Year
2020
Publication date
18.11.2020
Grundlagen der GPC, Prinzipien und Möglichkeiten
Sowohl bei natuerlichen als auch synthetischen Polymeren spielt die Klaerung von Groesse, Zusammensetzung, Struktur und Kettenlaengenverteilung eine bedeutende Rolle. Eine geeignete Analysenmethode…
Language
Publication Number
20112
Publication Type
Published Paper
Source
CLB Chemie in Labor und Biotechnik
Year
1999
Publication date
07.01.1999
Issue
1
Author
T. Hofe, G. Reinhold
Grüne Gelpermeations-/ Größenausschlusschromatographie
Ressourcenschonendes Vorgehen und der Einsatz möglichst weniger umwelt- und gesundheitsschädlicher Lösungsmittel sind zentrale Forderungen der grünen Chemie, die in den letzten Jahren zunehmend an…
Language
Publication Number
20511
Publication Type
Published Paper
Source
GIT Labor-Fachzeitschrift
Year
2020
Publication date
09.09.2020
Author
J. Preis, D. Held, V. Hofmann
Gruppierung von Overlay-Ergebnis-Tabellen mit dem ReportDesignerplus
Müssen Sie Reproduzierbarkeiten bestimmen? Führen Sie Mehrfachinjektionen durch? Sie glauben gar nicht, wieviel Zeit Sie bei der Auswertung mit dem ReportDesignerplus und dem passenden Report sparen…
lockSign in for download
Language
Publication Number
30205
Publication Type
WinGPC Application
Source
PSS WinGPC Newsletter
Year
2009
Publication date
26.05.2009
Issue
2
Gültigkeit Kalibrierkurve
Überprüfen Sie ob Ihre Probe vollständig im kalibrierten Bereich eluiert.
lockSign in for download
Language
Publication Number
30031
Publication Type
WinGPC Application
Source
PSS WinGPC Newsletter
Year
2001
Publication date
15.02.2001
Issue
1
X

Die Webseite ist für moderne Browser optimiert. In Ihrem Browser können Inhalte fehlerhaft angezeigt werden.